Garage door opener error codes
In short: Most openers report problems by flashing a light a set number of times. On newer LiftMaster and Chamberlain openers, count the UP and DOWN arrow flashes (1 UP, 1 DOWN is code 1-1, a safety sensor problem). Older ones flash an LED next to the learn button, and Genie openers blink a status light. Find your pattern below.
LiftMaster and Chamberlain UP and DOWN arrow codes
Openers with UP and DOWN arrows on the motor unit, including Security+ 2.0 (yellow learn button) and Security+ 3.0 (white learn button) models. Codes 3-5 and 5-5 apply only to the 8500W/RJO70, 98022/RJO101 and 98032 wall-mount openers.
- 1-1 Safety sensors blocked, misaligned, disconnected or a wire is broken
- 1-2 Safety sensor wires reversed or shorted
- 1-5 RPM not detected
- 1-6 Unexpected door movement
- 2-1 to 2-5 Logic board component failure
- 3-5 Cable tension monitor (certain wall-mount models)
- 4-1 Resistance while closing
- 4-2 Resistance while opening
- 4-3 RPM lost while closing
- 4-4 RPM lost while opening
- 4-5 Unrecognized travel module
- 5-5 Remote light required for unattended operation (certain wall-mount models)
LiftMaster and Chamberlain flashing LED next to the learn button
Openers without UP and DOWN arrows, such as many AC openers and some earlier DC models. The maker notes that openers and replacement logic boards made after 2022 no longer have this feature.
LiftMaster and Chamberlain opener light flashing
Many LiftMaster and Chamberlain openers. The maker notes that on older units you could close the door by holding the wall button, but openers and logic boards made after February 3, 2022 no longer allow this.
Genie Excelerator screw-drive blink codes
Genie Excelerator screw-drive models H8000, H8000-07, H8000D, ISD990, ISD995, ISD1000, PRO99, PRO99-21C, PRO99FN and CMD9900.
Genie ChainLift, ReliaG, BeltLift and QuietLift LED codes
Genie models 1022 (ChainLift 600), 1024 (ReliaG 600), 1042 (BeltLift 600), 2022 (ChainLift 800), 2024 (ReliaG 800), 2027 (ChainLift 700) and 2042 (QuietLift 800).
- Red light on steady Programming incomplete
- Red light, 1 blink Remote not learned
- Green light, 1 blink Limits not set, or the door was obstructed
- Green light, 2 blinks Up limit not set, a wiring fault, or the safety sensors are out of line or blocked
- Green light, 3 blinks Limits set backwards
- Green light, 4 blinks Wall button wire shorted or reversed
- Green light, 5 blinks Chain or belt too tight, or control system failure
Find the model number on the label on the motor unit, then look up its manual. See where to find the model number, or check which remote technology your opener uses.