LiftMaster and Chamberlain UP and DOWN arrow codes
How to read it: Count how many times the UP arrow flashes, then how many times the DOWN arrow flashes. The pattern repeats; count it twice to be sure. 1 UP flash then 1 DOWN flash is code 1-1.
Applies to: Openers with UP and DOWN arrows on the motor unit, including Security+ 2.0 (yellow learn button) and Security+ 3.0 (white learn button) models. Codes 3-5 and 5-5 apply only to the 8500W/RJO70, 98022/RJO101 and 98032 wall-mount openers.
| Code | Meaning | What you see |
|---|---|---|
| 1-1 | Safety sensors blocked, misaligned, disconnected or a wire is broken | The door starts to close, then reverses back up. |
| 1-2 | Safety sensor wires reversed or shorted | The door stays open and will not close; it does not move down at all. |
| 1-5 | RPM not detected | The opener hums or clicks, and the door moves only a few inches or not at all. |
| 1-6 | Unexpected door movement | The door opens fully, then drifts down or moves on its own. |
| 2-1 to 2-5 | Logic board component failure | The opener does not respond normally to commands. |
| 3-5 | Cable tension monitor (certain wall-mount models) | The door reverses to open while closing, or does not move. |
| 4-1 | Resistance while closing | The door reverses, stops or struggles while closing. |
| 4-2 | Resistance while opening | The door stops before it is fully open. |
| 4-3 | RPM lost while closing | The door stops and reverses just before reaching the floor. |
| 4-4 | RPM lost while opening | The door stops before it is fully open. |
| 4-5 | Unrecognized travel module | The door starts to close and returns open, or does not move. |
| 5-5 | Remote light required for unattended operation (certain wall-mount models) | Scheduled, app or automation commands do not run, but the wall control and remotes still work. |
Safety
If a code points to a heavy or unbalanced door, do not keep running the opener and do not adjust springs or cables yourself. They are under high tension. Find a technician.