What you will notice
The door starts to close and returns open, or does not move.
What you can safely check
- If a part was replaced recently, confirm it is the correct travel module for your model using the model number and manual.
An installer can fit the correct part.
Does this code apply to my opener?
Openers with UP and DOWN arrows on the motor unit, including Security+ 2.0 (yellow learn button) and Security+ 3.0 (white learn button) models. Codes 3-5 and 5-5 apply only to the 8500W/RJO70, 98022/RJO101 and 98032 wall-mount openers. Count how many times the UP arrow flashes, then how many times the DOWN arrow flashes. The pattern repeats; count it twice to be sure. 1 UP flash then 1 DOWN flash is code 1-1.
Codes differ between models, and not every model or software version shows the same pattern. Confirm with the manual for your model. Find your model number.
Other liftmaster and chamberlain up and down arrow codes
- 1-1: Safety sensors blocked, misaligned, disconnected or a wire is broken
- 1-2: Safety sensor wires reversed or shorted
- 1-5: RPM not detected
- 1-6: Unexpected door movement
- 2-1 to 2-5: Logic board component failure
- 3-5: Cable tension monitor (certain wall-mount models)
- 4-1: Resistance while closing
- 4-2: Resistance while opening
- 4-3: RPM lost while closing
- 4-4: RPM lost while opening
- 5-5: Remote light required for unattended operation (certain wall-mount models)