What you will notice
The door reverses, stops or struggles while closing.
What you can safely check
- Remove obstructions from the door's path and tracks.
- Look for damaged rollers or hinges; lubricate hinges and roller bearings with a garage door lubricant.
- If the door goes past the floor, reprogram the travel limits as the manual describes.
If it continues, have the door's balance and hardware checked.
Does this code apply to my opener?
Openers with UP and DOWN arrows on the motor unit, including Security+ 2.0 (yellow learn button) and Security+ 3.0 (white learn button) models. Codes 3-5 and 5-5 apply only to the 8500W/RJO70, 98022/RJO101 and 98032 wall-mount openers. Count how many times the UP arrow flashes, then how many times the DOWN arrow flashes. The pattern repeats; count it twice to be sure. 1 UP flash then 1 DOWN flash is code 1-1.
Codes differ between models, and not every model or software version shows the same pattern. Confirm with the manual for your model. Find your model number.
Other liftmaster and chamberlain up and down arrow codes
- 1-1: Safety sensors blocked, misaligned, disconnected or a wire is broken
- 1-2: Safety sensor wires reversed or shorted
- 1-5: RPM not detected
- 1-6: Unexpected door movement
- 2-1 to 2-5: Logic board component failure
- 3-5: Cable tension monitor (certain wall-mount models)
- 4-2: Resistance while opening
- 4-3: RPM lost while closing
- 4-4: RPM lost while opening
- 4-5: Unrecognized travel module
- 5-5: Remote light required for unattended operation (certain wall-mount models)