What you will notice
The wall control's light or screen is not lit, or the wall button does not work.
What you can safely check
- Look for a staple or damage on the wall-control wires.
- Try a replacement wall control if the wiring is sound.
The maker notes that the wire-shorting test described for older units does not work on Security+ 2.0 openers.
Does this code apply to my opener?
Openers without UP and DOWN arrows, such as many AC openers and some earlier DC models. The maker notes that openers and replacement logic boards made after 2022 no longer have this feature. Watch the small LED next to the LEARN button on the motor unit. It flashes a number of times, pauses, and repeats. Count the flashes.
Codes differ between models, and not every model or software version shows the same pattern. Confirm with the manual for your model. Find your model number.